Accès gratuit
Numéro
Med Sci (Paris)
Volume 32, Numéro 8-9, Août–Septembre 2016
Page(s) 732 - 738
Section M/S Revues
DOI https://doi.org/10.1051/medsci/20163208021
Publié en ligne 12 septembre 2016
  1. Caton J, Papin P. Typologie et épidémiologie des prothèses totales de hanche en France. E-mémoires de l’Académie Nationale de Chirurgie 2012 ; 11 : 1–7.
  2. Chiron P. Le resurfaçage total de la hanche : le retour du passé ou une arthroplastie moderne ? E-mémoires de l’Académie Nationale de Chirurgie 2008 ; 7 : 07–12.
  3. Estey MP, Diamandis EP, Van Der Straeten C, et al. Cobalt and chromium measurement in patients with metal hip prostheses. Clin Chem 2013 ; 59 : 880–886. [CrossRef] [PubMed]
  4. Christofilopoulos P, Lübbeke A, Peter R, Hoffmeyer P. Le point sur la prothèse totale de hanche. Rev Med Suisse 2010 ; 6 : 2454–2458.
  5. American Academy of Orthopaedic Surgeons. Information statement 2012, current concerns with metal-on-metal hip arthroplasty. Available at: www.aaos.org/about/papers/advistmt/1035, consulté en octobre 2015.
  6. Delaunay C, Petit I, Learmonth ID, et al. Metal-on-metal bearings total hip arthroplasty: the cobalt and chromium ions release concern. Orthop Traumatol Surg Res 2010 ; 96 : 894–904. [CrossRef]
  7. Valcu CA, Perdreau A, Wouters A, Gillet P. Les inquiétudes liées au couple métal-métal dans les prothèses totales de hanche sont-elles fondées en 2012 ? Rev Méd Liège 2013 ; 68 : 32–37.
  8. Hart AJ, Quinn PD, Lali F, et al. Cobalt from metal-on-metal hip replacements may be the clinically relevant active agent responsible for periprosthetic tissue reactions. Acta Biomaterialia 2012 ; 8 : 3865–3873. [CrossRef] [PubMed]
  9. Agence fédérale des médicaments et des produits de santé. Available at: www.afmps.be, consulté en octobre 2015.
  10. Lauwerys R. Toxicologie industrielle et intoxications professionnelles. Paris : Masson, 2007 : 1142 p.
  11. Simonsen LO, Harbak H, Bennekou P. Cobalt metabolism and toxicology:a brief update. Sci Total Environ 2012 ; 432 : 210–215. [CrossRef] [PubMed]
  12. Barceloux DG. Cobalt. J Toxicol Clin Toxicol 1999 ; 37 : 201–206. [CrossRef] [PubMed]
  13. Lippi G, Franchini M, Guidi GC. Cobalt chloride administration in athletes: a new perspective in blood doping? Br J Sports Med 2005 ; 39 : 872–873. [CrossRef] [PubMed]
  14. Institut national de recherche et de sécurité. Available at: www.inrs.fr, consulté en octobre 2015.
  15. Commission de la santé et de la sécurité du travail. Available at : www.csst.qc.ca/prevention/reptox, consulté en octobre 2015.
  16. Apostoli P, Catalani S, Zaghini A, et al. High doses of cobalt induce optic and auditory neuropathy. Exp Toxicol Pathol 2013 ; 65 : 719–727. [CrossRef] [PubMed]
  17. Lauwerys R, Lison D. Health risks associated with cobalt exposure: an overview. Sci Total Environ 1994 ; 150 : 1–6. [CrossRef]
  18. Langton DJ, Sidaginamale RP, Joyce TJ, et al. The clinical implications of elevated blood metal ion concentrations in asymptomatic patients with MoM hip resurfacings: a cohort study. BMJ Open 2013 ; 3 : e001541. [CrossRef] [PubMed]
  19. Triclot P. Leçons à tirer de l’étude toxicologique d’une série continue de prothèses totales de hanche à couple métal-métal. Rev Chir Orthop Traumatol 2011 ; 97S : 9–12.
  20. Catalani S, Rizzetti MC, Padovani A, Apostoli P. Neurotoxicity of cobalt. Hum Exp Toxicol 2012 ; 31 : 421–437. [CrossRef] [PubMed]
  21. Wong CC, Nixon RL. Systemic allergic dermatitis caused by cobalt and cobalt toxicity from a metal on a metal hip replacement. Contact Derm 2014 ; 71 : 113–114. [CrossRef]
  22. Gessner BD, Steck T, Woelber E, Tower SS. A systematic review of systemic cobaltism after wear or corrosion of chrome-cobalt hip implants. J Patient Saf 2016 (sous presse).
  23. Paustenbach DJ, Galbraith DA, Finley BL. Interpreting cobalt blood concentrations in hip implant patients. Clin Toxicol (Phila) 2014 ; 52 : 98–112. [CrossRef] [PubMed]
  24. Bradberry SM, Wilkinson JM, Ferner RE. Systemic toxicity related to metal hip prostheses. Clin Toxicol (Phila) 2014 ; 52 : 837–847. [CrossRef] [PubMed]
  25. Finley BL, Monnot AD, Gaffney SH, Paustenbach DJ. Dose-response relationships for blood cobalt concentrations and health effects: a review of the literature and application of a biokinetic model. J Toxicol Environ Health B Crit Rev 2012 ; 15 : 493–523. [CrossRef] [PubMed]
  26. Christian WV, Oliver LD, Paustenbach DJ, et al. Toxicology-based cancer causation analysis of CoCr-containing hip implants: a quantitative assessment of genotoxicity and tumorigenicity studies. J Appl Toxicol 2014 ; 34 : 939–967. [CrossRef] [PubMed]
  27. DeSouza RM, Wallace D, Costa ML, Krikler SJ. Transplacental passage of metal ions in women with hip resurfacing: no teratogenic effects observed. Hip Int 2012 ; 22 : 96–99. [CrossRef] [PubMed]
  28. Gustafson K, Jakobsen SS, Lorenzen ND, et al. Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis: 5-year follow-up of 52 patients. Acta Orthop 2014 ; 85 : 348–354. [CrossRef] [PubMed]
  29. Hartmann A, Hannemann F, Lützner J, et al. Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing–systematic review of clinical and epidemiological studies. PLoS One 2013 ; 8 : e70359. [CrossRef] [PubMed]
  30. Sidaginamale RP, Joyce TJ, Lord JK, et al. Blood metal ion testing is an effective screening tool to identify poorly performing metal-on-metal bearing surfaces. Bone Joint Res 2013 ; 2 : 84–95. [CrossRef]
  31. Hart AJ, Sabah SA, Sampson B, et al. Surveillance of patients with metal-on-metal hip resurfacing and total hip prostheses. J Bone Joint Surg Am 2014 ; 96 : 1091–1099. [CrossRef]
  32. Griffin WL. Metal ion levels: how can they help us? J Arthroplasty 2014 ; 29 : 659–660. [CrossRef] [PubMed]
  33. Randelli F, Banci L, Favilla S, et al. Radiographically undetectable periprosthetic osteolysis with ASR implants: the implication of blood metal ions. J Arthroplasty 2013 ; 28 : 1259–1264. [CrossRef] [PubMed]
  34. Back DL, Young DA, Shimmin AJ. How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing? Clin Orthop Relat Res 2005 ; 438 : 177–181. [CrossRef] [PubMed]
  35. Hannemann F, Hartmann A, Schmitt J, et al. European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing. Orthop Traumatol Surg Res 2013 ; 99 : 263–271. [CrossRef]
  36. Nicolli A, Bisinella G, Padovani G, et al. Predictivity and fate of metal ion release from metal-on-metal total hip prostheses. J Arthroplasty 2014 ; 29 : 1763–1767. [CrossRef] [PubMed]
  37. Lass R, Grübl A, Kolb A, et al. Comparison of synovial fluid, urine, and serum ion levels in metal-on-metal total hip arthroplasty at a minimum follow-up of 18 years. J Orthop Res 2014 ; 32 : 1234–1240. [CrossRef]
  38. Mistretta V, Charlier C. Le dosage du cobalt dans le sang par ICP-MS : application aux patients porteurs de prothèses de hanche en métal. Toxicol Anal Clin 2015 ; 27 : 91–98.
  39. Cohen D. How safe are metal-on-metal hip implants? BMJ 2012 ; 344 : 1410–1417. [CrossRef]
  40. Cesbron A, Saussereau E, Mahieu L, et al. Metallic profile of whole blood and plasma in a series of 106 healthy volunteers. J Anal Toxicol 2013 ; 37 : 401–405. [CrossRef] [PubMed]
  41. Mao X, Wong AA, Crawford RW. Cobalt toxicity: an emerging clinical problem in patients with metal-on-metal hip prostheses? Med J Aust 2011 ; 194 : 649–651. [PubMed]

Les statistiques affichées correspondent au cumul d'une part des vues des résumés de l'article et d'autre part des vues et téléchargements de l'article plein-texte (PDF, Full-HTML, ePub... selon les formats disponibles) sur la platefome Vision4Press.

Les statistiques sont disponibles avec un délai de 48 à 96 heures et sont mises à jour quotidiennement en semaine.

Le chargement des statistiques peut être long.